P2AF6: Wagoneer starter-relay indication from an unseated connector

The bulletin associates P2AF6-00, described here as starter relay 3 stuck off, with disabled stop/start.

Read before applying this article

Documented application

FCA 08-138-23 concerns North American 2022–2023 Wagoneer/Grand Wagoneer WS built August 24, 2022–March 8, 2023.

The code alone does not identify a failed part or establish that a vehicle is safe to drive. Confirm the vehicle, reporting module and applicable service procedure.

A relay label can hide a connection problem

The bulletin associates P2AF6-00, described here as starter relay 3 stuck off, with disabled stop/start. Its stated cause is a connector that is not fully seated at the power-distribution center. This is a specific reason to inspect the connection before ordering a relay or complete distribution assembly.

The physical finding controls the action

FCA identifies connector D3157A and distinguishes a properly connected unit from one that needs reseating. The repair does not say to replace the power-distribution center solely from the code. Access and reconnection must follow the correct service procedure so the original seating issue is not replaced by a new connection fault.

Verification checks pending status too

The source requires five stop/start events within one drive cycle, confirmation that warning lamps do not appear and a check that P2AF6 is not pending. A successful engine start or an empty active-code list alone is weaker evidence than that prescribed verification. If the code resets, the bulletin explicitly sends the technician back to normal diagnosis. Confirm the build window and exact application, preserve the connector finding and document the retest. This case does not establish that every P2AF6 is a loose connector or authorize bypassing the starter-control circuit.

Source and applicability

FCA 08-138-23 concerns North American 2022–2023 Wagoneer/Grand Wagoneer WS built August 24, 2022–March 8, 2023.

Manufacturer bulletin, page 1 · Manufacturer bulletin, page 2 · Manufacturer bulletin, page 3

Article source documents

  1. FCA US LLC / Stellantis

    0813823 — NHTSA manufacturer communication 10241073

Source checks describe how the text was prepared; they do not certify a diagnosis or confirm compatibility with every vehicle using this code.

Original code reference

Dictionary definition

Starter Relay C Stuck Off

This definition retains its original catalog scope. The article above is limited to its explicitly documented application.

Reference scope

Generic OBD-II definition.

A manufacturer label does not establish the model, year, engine or module to which a diagnosis applies. Read the safety and diagnostic limits.