Diagnostic article Generic OBD-II
P0C14: motor B phase U overheating depends on PIM Temp 2 validity
GM P0C14 evaluates an in-range inverter thermal condition with separate initial-fault and recovery boundaries.
Read before applying this article
Documented application
GM 2010 10OBDG10 Hybrid Diagnostics, cited BPCM or hybrid-controller monitor only. Historical calibration values are not universal specifications; no per-code model, engine or hardware fitment has been established.
The code alone does not identify a failed part or establish that a vehicle is safe to drive. Confirm the vehicle, reporting module and applicable service procedure.
P0C14 is the motor B inverter phase U overtemperature code in the cited GM document. The row uses PIM Temp 2, not an assumed first temperature channel based on phase lettering. Match that mapping to the actual controller before identifying hardware.
The sensor must support a thermal conclusion
The source requires an in-range PIM temperature and inactive P0BE1 performance fault. Those conditions are important because a direct circuit fault can make a reported temperature unsuitable for a physical overheating diagnosis.
GM gives an initial boundary above 88°C and a lower 85°C reset boundary. The monitor uses 500 qualifying counts among 650 at a 10.4 ms rate and lists one-trip reporting. Detection is therefore a filtered thermal event, not merely one scan refresh near a numerical limit.
Record the history needed for verification
Preserve the temperature trend, related sensor faults and operating context before the system cools. A later normal reading cannot establish why the event occurred or whether its cause remains.
The table does not identify a specific cooling component or mandate inverter replacement. A qualified hybrid technician must follow the actual vehicle procedure to establish the cause and confirm credible recovery under eligible operation. Physical inverter access requires proper high-voltage isolation. These historical thresholds must not be used to justify deliberately forcing the system into an overheated state.
Source and applicability
GM 2010 10OBDG10 Hybrid Diagnostics, cited BPCM or hybrid-controller monitor only. Historical calibration values are not universal specifications; no per-code model, engine or hardware fitment has been established. GM PDF, physical page 302.
Article source documents
Source checks describe how the text was prepared; they do not certify a diagnosis or confirm compatibility with every vehicle using this code.
Original code reference
Dictionary definition
Drive Motor B Inverter Phase U Over Temperature
This definition retains its original catalog scope. The article above is limited to its explicitly documented application.
Reference scope
Generic OBD-II definition.
A manufacturer label does not establish the model, year, engine or module to which a diagnosis applies. Read the safety and diagnostic limits.
Definition source
- DTC Database: pinned community code definitions
Source checked · MIT